Common Problems Related to Sliding Bowl Bottom

If the sliding mechanism fails, several issues occur:

Bowl not closing

Sludge not discharging

  • blocked ports
  • excessive sludge buildup

Continuous oil loss

  • damaged seals
  • improper hydraulic pressure

Vibration

  • improper assembly
  • worn components

These problems directly affect purifier performance.


Maintenance and Inspection Tips

Engineers you should:

  • inspect O-rings and seals regularly
  • clean sludge ports during overhaul
  • check hydraulic passages for blockage
  • ensure correct operating water pressure
  • replace worn sealing rings
  • assemble parts correctly and balance bowl

Regular maintenance prevents hydraulic failure.


Signs of Fault

During operation, watch for:

  • sludge not discharging
  • purifier overflowing
  • frequent alarms
  • oil leakage
  • abnormal vibration

These may indicate sliding bowl bottom problems.